Contribution

Validation of the German Matrix Test in a Remote Testing Application

* Presenting author
Day / Time: 19.03.2025, 15:20-16:00
Typ: Poster
Information: The posters will be exhibited in Hall E north from Tuesday to Thursday, sorted by thematic context in the poster island indicated in the session title. The poster session at the specified time offers the opportunity to enter into discussion with the authors.
Abstract: Remote testing via smartphone or tablet yields several advantages, e.g., an easy access to a large population of subjects. For such remote assessments, the closed-set German Matrix sentence-in-noise Test is advantageous due to its international applicability and its high sensitivity and reliability. However, the results of remote testing need to be comparable to those obtained from laboratory measurements. Hence, a validation study involving 20 participants without hearing aid indications was conducted in order to investigate the test’s reliability and comparability in remote settings. Participants performed the German Matrix Test in a randomized order: once as laboratory test and twice with the remote testing application "Virtual Hearing Clinic” (VHC) with uncalibrated hardware including smartphones, tablets, laptops and headphones.First results show statistically significant correlations in test-retest measurement via VHC of r = 0.82 and between VHC test measurement and lab measurement of r = 0.75. In addition, a bias in speech recognition thresholds of 0.56 dB is observed between lab and VHC measurements. Overall, the validity of the German Matrix Test in the remote testing approach via the VHC could be demonstrated.